Differential Scanning Calorimetry (DSC) data for Curing Kinetics Study of thermoset based structural adhesive Henkel Teroson EP5089
Description
The attached data is the differential scanning calorimetry data for Henkel Teroson EP5089.
Publication Date
12-10-2021
Publisher
Mendeley Data
DOI
10.17632/tt87pfzkkg.1
Document Type
Data Set
Recommended Citation
AGHA, AKSHAT (2021), "Differential Scanning Calorimetry (DSC) data for Curing Kinetics Study of thermoset based structural adhesive Henkel Teroson EP5089", Mendeley Data, doi: 10.17632/tt87pfzkkg.1
https://doi.org/10.17632/tt87pfzkkg.1
Identifier
tt87pfzkkg
Methodology
The tests were performed on a TA Instruments DSC for isothermal heating ramps of 0.5K/min, 1K/min, 2K/min, and 5K/min. The enthalpies from the tests are provided. The enthalpies were integrated to obtain the degree of cure with time and temperature.
Embargo Date
12-10-2021
Version
1