Date of Award

8-2022

Document Type

Dissertation

Degree Name

Doctor of Philosophy (PhD)

Department

Civil Engineering

Committee Chair/Advisor

Dr. Bradley J. Putman

Committee Member

Dr. Prasad Rao Rangaraju

Committee Member

Dr. Amir Poursaee

Committee Member

Dr. Whitney Huang

Abstract

The objective of this study was to characterize the variability of dynamic modulus of asphalt mixes in South Carolina on the basis of geometry and anisotropy. High priority mixes Surface Type B, and C; Intermediate Type B and C and Base Type A from three different days of production were collected from seven different contractors each having a different aggregate source and the dynamic modulus was measured using the Asphalt Mixture Performance Tester (AMPT) at temperatures of 40, 70, 100 and 130℉ (4.4, 21.1, 37.8, and 54.4℃) and at frequencies of 25, 10, 5, 1, 0.5, and 0.1 Hz. One-way ANOVA test was conducted on the control specimen to find the variability of dynamic modulus between mix types and contractor. The results showed that there were no significant differences between the contractors for Intermediate mixes and Surface C and some, but little, variability in Base A and Surface B mix. Also, at higher temperatures (70, 100 and 130℉) and lower frequencies, there was less variability between the mixes for a given contractor. The feasibility of having small-scale specimen was analyzed and the results show that reducing the specimen size from 100 mm x 150 mm to 38 mm to 110 mm has direct effect on dynamic modulus and the small-scale specimen had reduction in dynamic modulus as well. The ratio of small-scale to the control specimen ranged from 0.81 to 1.23 with an average of 0.96. The feasibility of having specimen cored horizontally was studied so that determining the dynamic modulus of field cores are possible where each individual layer could be extracted from the composite specimen to study the pavement performance. The horizontally cored specimen exhibited an opposite trend to the vertically cored specimen, where there was an increase in dynamic modulus. The horizontally cored specimen exhibited higher dynamic modulus than the control specimen. The ratio of small-scale horizontal to control specimen ranged from 0.84 to 1.32 with an average of 1.06. The mastercurves generated for control and small-scale samples indicated that the horizontally cored specimen was in alignment with the control specimen than the vertically cored specimen. It also showed that the small-scale specimen had little to no variability in dynamic modulus with the control specimen at lower temperatures. There was high variability at high temperatures irrespective of mic type and contractor. The pavement performance using the PavementME indicated that horizontally cored small-scale specimen was highly resistant to AC layer deformation and prone to top-down cracking. But the opposite trend was observed in the vertically cored small-scale specimen where it was prone to rutting and resistant to cracking. This is solely because the horizontal specimen had higher dynamic modulus while the vertically cored specimen had lower dynamic modulus. The dynamic modulus data on field cores cored horizontally indicates the feasibility of testing the field specimen with a reduced dimension. Banks SMA had similar dynamic modulus for both field cores and plant mix-lab compacted cores. The lab/field performance was close to 1 for all the distresses except top-down cracking which was found to be 0.85. The above result was an indication that the mixes produced at the plant and compacted at the lab was an ideal representation of actual pavement in the field.

Author ORCID Identifier

0000-0002-3382-2858

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.