Date of Award

5-2022

Document Type

Thesis

Degree Name

Master of Science (MS)

Department

Bioengineering

Committee Chair/Advisor

Dr. Bruce Gao

Committee Member

Dr. Martine LaBerge

Committee Member

Dr. Ethan Kung

Abstract

Cardiovascular diseases are the leading cause of death in the United States. Atherosclerosis in peripheral arteries is a major contributing factor. Autologous saphenous vein grafts are the most common bypass grafts for treating peripheral artery diseases. A quarter of these grafts fail within a year, and around half have failed within 10 years of the initial surgery. Graft failure is attributed to the development of intimal hyperplasia indicated by the migration and proliferation of vascular smooth muscle cells, fibroblasts, and the deposition of extracellular proteins.

Increases in flow, pressure, the pulse frequency, and the differential of pressure that model an arterial environment have been shown to trigger intimal hyperplasia. These tend to occur at the sites of flow disruption most often associated with the anastomotic sites. Turbid blood flow due to flow separation and flow reversal promote positive factors for intimal hyperplasia.

Perfusion bioreactors have allowed researchers to study vein grafts ex-vivo, creating a better understanding of vein remodeling. The goal of this project was to emulate the pressure, flow, and pulse frequency of the peripheral arterial environment. We developed a lab-built four-channel pulsatile flow perfusion bioreactor, which has the unique design features for testing varying vascular grafts and grafting techniques using optical coherence tomography and particle imaging velocimetry.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.